Figure 1.
Attrition Plot
Attrition Plot

ICD indicates implantable cardioverter-defibrillator; NCDR, National Cardiovascular Data Registry.

Figure 2.
Factors Associated With Not Performing Defibrillation Testing
Factors Associated With Not Performing Defibrillation Testing

ACE indicates angiotensin-converting enzyme; Afib, atrial fibrillation; ARB, angiotensin receptor blocker; CABG, coronary artery bypass graft; CR, cardiac resynchronization; CRT-D, cardiac resynchronization therapy with defibrillator; EP, electrophysiologist; EPF, electrophysiology fellowship; FDT, final device type; HB, heart block; HRS, Heart Rhythm Society; NYHA, New York Heart Association; and TCS, thoracic cardiac surgery.

aVariable with more than 2 categories.

Figure 3.
Temporal Trends in Defibrillation Testing
Temporal Trends in Defibrillation Testing

The percentage of use of defibrillation testing among all hospitals per quarter (Q) from April 2010 to December 2015.

Figure 4.
Hospital-Level Variation in Use of Defibrillation Testing
Hospital-Level Variation in Use of Defibrillation Testing

The median (center line) and interquartile range (top and bottom borders of box) of defibrillation testing with median odds ratio for each study year. Whiskers bars indicate 95% CI; circles, outliers.

Table.  
Baseline Patient, Clinician, and Hospital Characteristics Stratified by DFT
Baseline Patient, Clinician, and Hospital Characteristics Stratified by DFT
1.
Moss  AJ, Zareba  W, Hall  WJ,  et al; Multicenter Automatic Defibrillator Implantation Trial II Investigators.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.  N Engl J Med. 2002;346(12):877-883. doi:10.1056/NEJMoa013474PubMedGoogle ScholarCrossref
2.
Kadish  A, Dyer  A, Daubert  JP,  et al; Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) Investigators.  Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy.  N Engl J Med. 2004;350(21):2151-2158. doi:10.1056/NEJMoa033088PubMedGoogle ScholarCrossref
3.
Bardy  GH, Lee  KL, Mark  DB,  et al; Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.  N Engl J Med. 2005;352(3):225-237. doi:10.1056/NEJMoa043399PubMedGoogle ScholarCrossref
4.
Epstein  AE, DiMarco  JP, Ellenbogen  KA,  et al; American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices); American Association for Thoracic Surgery; Society of Thoracic Surgeons.  ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons.  Circulation. 2008;117:e350-e408.PubMedGoogle Scholar
5.
Tracy  CM, Epstein  AE, Darbar  D,  et al.  2012 ACCF/AHA/HRS focused update of the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines.  J Am Coll Cardiol. 2012;60:1297-1313. doi:10.1016/j.jacc.2012.07.009PubMedGoogle ScholarCrossref
6.
Russo  AM, Chung  MK.  Is defibrillation testing necessary for implantable transvenous defibrillators? defibrillation testing is necessary at the time of implantable cardioverter defibrillator implantation.  Circ Arrhythm Electrophysiol. 2014;7(2):337-346. doi:10.1161/CIRCEP.113.000371PubMedGoogle ScholarCrossref
7.
Swerdlow  CD, Russo  AM, Degroot  PJ.  The dilemma of ICD implant testing.  Pacing Clin Electrophysiol. 2007;30(5):675-700. doi:10.1111/j.1540-8159.2007.00730.xPubMedGoogle ScholarCrossref
8.
Blatt  JA, Poole  JE, Johnson  GW,  et al; SCD-HeFT Investigators.  No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).  J Am Coll Cardiol. 2008;52(7):551-556. doi:10.1016/j.jacc.2008.04.051PubMedGoogle ScholarCrossref
9.
Matassini  MV, Healey  JS.  How to manage a high defibrillation threshold in ICD patients and does it really matter.  Curr Treat Options Cardiovasc Med. 2013;15(4):497-505. doi:10.1007/s11936-013-0244-7PubMedGoogle ScholarCrossref
10.
Pires  LA, Johnson  KM.  Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough?  J Cardiovasc Electrophysiol. 2006;17(2):140-145. doi:10.1111/j.1540-8167.2005.00294.xPubMedGoogle ScholarCrossref
11.
Healey  JS, Gula  LJ, Birnie  DH,  et al.  A randomized-controlled pilot study comparing ICD implantation with and without intraoperative defibrillation testing in patients with heart failure and severe left ventricular dysfunction: a substudy of the RAFT trial.  J Cardiovasc Electrophysiol. 2012;23(12):1313-1316. doi:10.1111/j.1540-8167.2012.02393.xPubMedGoogle ScholarCrossref
12.
Brignole  M, Occhetta  E, Bongiorni  MG,  et al; SAFE-ICD Study Investigators.  Clinical evaluation of defibrillation testing in an unselected population of 2,120 consecutive patients undergoing first implantable cardioverter-defibrillator implant.  J Am Coll Cardiol. 2012;60(11):981-987. doi:10.1016/j.jacc.2012.05.014PubMedGoogle ScholarCrossref
13.
Birnie  D, Tung  S, Simpson  C,  et al.  Complications associated with defibrillation threshold testing: the Canadian experience.  Heart Rhythm. 2008;5(3):387-390. doi:10.1016/j.hrthm.2007.11.018PubMedGoogle ScholarCrossref
14.
Poole  JE, Johnson  GW, Hellkamp  AS,  et al.  Prognostic importance of defibrillator shocks in patients with heart failure.  N Engl J Med. 2008;359:1009-1017. doi:10.1056/NEJMoa071098PubMedGoogle ScholarCrossref
15.
Hohnloser  SH, Dorian  P, Roberts  R,  et al.  Effect of amiodarone and sotalol on ventricular defibrillation threshold: the optimal pharmacological therapy in cardioverter defibrillator patients (OPTIC) trial.  Circulation. 2006;114(2):104-109. doi:10.1161/CIRCULATIONAHA.106.618421PubMedGoogle ScholarCrossref
16.
Gold  MR, Higgins  S, Klein  R,  et al.  Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS).  Circulation. 2002;105(17):2043-2048. doi:10.1161/01.CIR.0000015508.59749.F5PubMedGoogle ScholarCrossref
17.
Hammill  S, Phurrough  S, Brindis  R.  The National ICD Registry: now and into the future.  Heart Rhythm. 2006;3(4):470-473. doi:10.1016/j.hrthm.2006.01.019PubMedGoogle ScholarCrossref
18.
Masoudi  FA, Ponirakis  A, de Lemos  JA,  et al.  Trends in US cardiovascular care: 2016 report from 4 ACC national cardiovascular data registries.  J Am Coll Cardiol. 2017;69(11):1427-1450. doi:10.1016/j.jacc.2016.12.005PubMedGoogle ScholarCrossref
19.
Messenger  JC, Ho  KKL, Young  CH,  et al; NCDR Science and Quality Oversight Committee Data Quality Workgroup.  The National Cardiovascular Data Registry (NCDR) data quality brief: The NCDR data quality program in 2012.  J Am Coll Cardiol. 2012;60(16):1484-1488. doi:10.1016/j.jacc.2012.07.020PubMedGoogle ScholarCrossref
20.
Hsu  JC, Marcus  GM, Al-Khatib  SM,  et al.  Predictors of an inadequate defibrillation safety margin at ICD implantation: insights from the National Cardiovascular Data Registry.  J Am Coll Cardiol. 2014;64(3):256-264. doi:10.1016/j.jacc.2014.01.085PubMedGoogle ScholarCrossref
21.
Merlo  J, Chaix  B, Ohlsson  H,  et al.  A brief conceptual tutorial of multilevel analysis in social epidemiology: using measures of clustering in multilevel logistic regression to investigate contextual phenomena.  J Epidemiol Community Health. 2006;60(4):290-297. doi:10.1136/jech.2004.029454PubMedGoogle ScholarCrossref
22.
Healey  JS, Hohnloser  SH, Glikson  M,  et al; Shockless IMPLant Evaluation [SIMPLE] Investigators.  Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE).  Lancet. 2015;385(9970):785-791. doi:10.1016/S0140-6736(14)61903-6PubMedGoogle ScholarCrossref
23.
Bänsch  D, Bonnemeier  H, Brandt  J,  et al; NORDIC ICD Trial Investigators.  Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial.  Eur Heart J. 2015;36(37):2500-2507. doi:10.1093/eurheartj/ehv292PubMedGoogle ScholarCrossref
24.
Wilkoff  BL, Fauchier  L, Stiles  MK,  et al.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.  Heart Rhythm. 2016;13(2):e50-e86. doi:10.1016/j.hrthm.2015.11.018PubMedGoogle ScholarCrossref
25.
Pires  LA.  Defibrillation testing of the implantable cardioverter defibrillator: when, how, and by whom?  Indian Pacing Electrophysiol J. 2007;7(3):166-175.PubMedGoogle Scholar
26.
Russo  AM, Wang  Y, Al-Khatib  SM, Curtis  JP, Lampert  R.  Patient, physician, and procedural factors influencing the use of defibrillation testing during initial implantable cardioverter defibrillator insertion: findings from the NCDR®.  Pacing Clin Electrophysiol. 2013;36(12):1522-1531. doi:10.1111/pace.12248PubMedGoogle ScholarCrossref
27.
Echt  DS, Liebson  PR, Mitchell  LB,  et al.  Mortality and morbidity in patients receiving encainide, flecainide, or placebo: the Cardiac Arrhythmia Suppression Trial.  N Engl J Med. 1991;324(12):781-788. doi:10.1056/NEJM199103213241201PubMedGoogle ScholarCrossref
28.
Han  H, Chao  H, Guerra  A,  et al.  Evolution of the American College of Cardiology/American Heart Association Clinical Guidelines.  J Am Coll Cardiol. 2015;65(25):2726-2734. doi:10.1016/j.jacc.2015.04.050PubMedGoogle ScholarCrossref
29.
Neuman  MD, Goldstein  JN, Cirullo  MA, Schwartz  JS.  Durability of class I American College of Cardiology/American Heart Association clinical practice guideline recommendations.  JAMA. 2014;311(20):2092-2100. doi:10.1001/jama.2014.4949PubMedGoogle ScholarCrossref
Limit 200 characters
Limit 25 characters
Conflicts of Interest Disclosure

Identify all potential conflicts of interest that might be relevant to your comment.

Conflicts of interest comprise financial interests, activities, and relationships within the past 3 years including but not limited to employment, affiliation, grants or funding, consultancies, honoraria or payment, speaker's bureaus, stock ownership or options, expert testimony, royalties, donation of medical equipment, or patents planned, pending, or issued.

Err on the side of full disclosure.

If you have no conflicts of interest, check "No potential conflicts of interest" in the box below. The information will be posted with your response.

Not all submitted comments are published. Please see our commenting policy for details.

Limit 140 characters
Limit 3600 characters or approximately 600 words
    Original Investigation
    Cardiology
    October 18, 2019

    Análisis de tendencias temporales y variación en el uso de pruebas de desfibrilación en la práctica contemporánea

    Author Affiliations
    • 1Division of Cardiology, University of Colorado Anschutz Medical Campus, Aurora, Colorado
    • 2Cone Health Medical Group HeartCare, Greensboro, North Carolina
    • 3Department of Medicine, Yale University School of Medicine, New Haven, Connecticut
    • 4Center of Outcomes and Research Evaluation, Yale-New Haven Health, New Haven, Connecticut
    • 5Department of Medicine, Denver Health Hospital, Denver, Colorado
    • 6Department of Medicine, Duke University School of Medicine, Durham, North Carolina
    • 7Department of Medicine, Rochester Hospital, Rochester, New York
    • 8Department of Medicine, Mayo Clinic, Rochester, Minnesota
    • 9Department of Medicine, University of California, San Diego, La Jolla
    • 10Department of Medicine, Cooper Medical School of Rowan University, Camden, New Jersey
    JAMA Netw Open. 2019;2(10):e1913553. doi:10.1001/jamanetworkopen.2019.13553
    Puntos claveEnglish 中文 (chinese)

    Pregunta  ¿Cuáles son las tendencias contemporáneas, la variación institucional y las características del paciente y del hospital relacionadas con las pruebas de desfibrilación entre los pacientes que se someten a la primera implantación del desfibrilador cardioversor implantable?

    Conclusiones  En este estudio transversal de 499 211 pacientes sometidos a la implantación del desfibrilador cardioversor implantable, hubo una disminución significativa en el uso de las pruebas de desfibrilación, aunque hubo un marcado aumento en la variación institucional.

    Significado  Existe una variabilidad en la desadoptación de las pruebas de desfibrilación que no se basa en las características del paciente y podría reflejar diferencias en las prácticas individuales o institucionales.

    Abstract

    Importance  Defibrillation testing (DFT) is performed during implantable cardioverter-defibrillator (ICD) implantation to assess the capacity of the device to detect and terminate ventricular arrhythmias. However, DFT can result in complications and omission of its use has been shown to be safe.

    Objective  To describe temporal trends and variation in the use of DFT in contemporary practice in the United States.

    Design, Setting, and Participants  This multicenter cross-sectional study used data from the National Cardiovascular Data Registry ICD Registry. A total of 499 211 patients from 1794 different facilities undergoing first-time ICD implantation from April 2010 to December 2015 were included. Data analysis was performed from May 20, 2015, to August 15, 2019.

    Exposure  Defibrillation testing was assessed using the National Cardiovascular Data Registry ICD Registry.

    Main Outcomes and Measures  Defibrillation testing rates and median odds ratios (MORs) were assessed over time. The MOR represents the odds that a randomly selected patient receiving testing at a hospital with high testing rates would be tested compared with if he or she had received care at a hospital with low testing rates.

    Results  Of the 499 211 patients from 1794 different facilities included in this analysis, the mean (SD) age of the population was 65.5 (13.4) years and 356 681 patients (71.4%) were men. The use of DFT declined from 71.6% in the first calendar quarter of 2010 to 36.4% in the fourth quarter of 2015 (P < .001). Patients undergoing DFT were more likely than those without testing to have ischemic heart disease (170 569 [58.1%] vs 116 295 [56.6%]), ventricular tachycardia (91 500 [31.2%] vs 58 949 [28.7%]), and less advanced heart failure (New York Heart Association class I and II, 153 188 [52.2%] vs 91 215 [44.4%]) (P < .001 for all). The MOR for the use of defibrillation testing was 3.78 (95% CI, 3.54-4.03) in 2010, increasing to 6.05 (95% CI, 5.61-6.52) in 2015, indicating that by 2015 a randomly selected patient receiving testing at a hospital with high testing rates would have a 6-fold higher odds of being tested than if they had received care at a hospital with low testing rates.

    Conclusions and Relevance  Defibrillation testing at the time of ICD placement in the United States may have declined over time; however, institutional variation in its use appears to be marked and increased. This variability in the reduced use of defibrillation testing could reflect differences in individual or institutional cultures of practice.

    Introduction

    Implantable cardioverter-defibrillators (ICDs) improve the survival of patients at high risk for sudden death.1-5 Defibrillation testing (DFT) provides a means to evaluate the ability of a newly implanted device to detect and terminate ventricular fibrillation. Defibrillation testing was routinely used in the randomized clinical trials for which they are indicated, is included in the US Food and Drug Administration’s labeling of ICDs, and the testing was adopted in routine clinical practice.6,7

    However, the benefits of DFT have not routinely been demonstrated. Several studies published between 2008 and 2012 found no association between routine testing and the efficacy of ICD shocks during follow-up or the risk of arrhythmic death.8-11 Furthermore, contemporary ICDs rarely fail in their ability to detect and treat ventricular arrhythmias. Improvements in device technology provide defibrillation thresholds that are typically 10 to 20 J less than the maximum ICD output such that successful defibrillation occurs in more than 90% of clinical shocks.6,10-16 Complications of DFT, while relatively rare, can be serious.11-14

    Given the evolution of the evidence and guidelines, we sought to evaluate contemporary temporal trends and institutional variation in DFT at the time of initial ICD implantation and determine patient and hospital characteristics associated with DFT within the National Cardiovascular Data Registry (NCDR) ICD Registry between 2010 and 2015. The results could provide a perspective on the deadoption of a widely used clinical practice.

    Methods
    Data Source

    Details of the NCDR ICD Registry have been reported previously.17-19 The Centers for Medicare & Medicaid Services mandated that data on all Medicare primary prevention implants be entered into the NCDR ICD Registry until the data collection requirement ended on February 15, 2018.17 The mandate was in effect during the study years for this analysis. The registry uses both a standardized data set and definitions, has requirements in place to ensure uniform data entry and transmission, and is subject to data quality checks. All data submissions are evaluated for errors and completeness. This information is summarized in an automated report that is sent to the participants after each data submission. The NCDR audit program, which includes hospital medical records reviews and blinded data abstractions, serves as an additional mechanism to assess the accuracy of the data and enables participants to identify areas for improved data entry. Use of the NCDR was approved by the ICD Registry Research and Publications Committee. Statistical analysis was approved by the Yale Center for Outcomes Research and Evaluation. The initial analysis was performed on May 20, 2015. Research involving the NCDR is covered under a waiver of informed consent. This study followed the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) reporting guideline for cross-sectional studies.

    Study Population

    All patients undergoing initial implantation of a transvenous primary or secondary prevention ICD (single chamber, dual chamber, or cardiac resynchronization with defibrillator) between April 2010 and December 2015 were included. Patients were excluded if their ICD procedure was a replacement of a prior system, a generator replacement, or a lead revision. Patients younger than 18 years were included but represented only 0.35% of the cohort. Patients receiving a nontransvenous ICD system or a subcutaneous ICD, as well as those without documentation about whether DFT was performed, were also excluded.

    Outcomes

    Defibrillation testing was ascertained through documentation as described in the ICD Registry V2.1. In-hospital adverse events (cardiac arrest, cardiac perforation, lead dislodgement, myocardial infarction, cardiac tamponade, peripheral embolus, transient ischemia attack or cerebrovascular accident, urgent cardiac surgery) and in-hospital death were identified from the NCDR ICD registry.

    Statistical Analysis

    Baseline characteristics were compared between patients who did and did not have DFT performed at the time of implantation using χ2 tests for categorical variables and 2-tailed, unpaired t tests for continuous variables. Continuous variables are presented as means (SDs) and categorical variables as frequency and percentage. Patient, hospital, and clinician factors were compared using the χ2 test for categorical variables and t test for continuous variables. Missing values were rare (≤1%) for all of the factors under consideration except left-ventricular ejection fraction (1.5%) and QRS interval duration (milliseconds) (7.1%); dummy variables indicating missing values for these factors were created and included in the models; missing values were imputed as the most frequent value of the categorical variables and the median of the continuous variables in the models. A multivariable analysis was performed to identify the patient and hospital factors associated with the use of DFT. Variables in the model were selected based on clinical experience and prior literature and included patient demographics, clinical characteristics, physician training, and hospital characteristics. Complications and death were adjusted using similar variables.

    To assess temporal changes in DFT, we examined its use since 2010 by quarters and tested the trend using the Cochran-Armitage trend test. Subgroup analysis was then performed to assess trends in specific patient populations, including primary and secondary prevention indication, and patients with structural abnormalities, including hypertrophic cardiomyopathy and congenital heart disease. We also assessed use in patients according to their estimated risk for an elevated defibrillation threshold based on a risk score previously derived and validated in the NCDR ICD Registry.20 This score is calculated based on the following characteristics: age younger than 70 years (1 point), male sex (1 point), black race (4 points), Hispanic ethnicity (2 points), other race/ethnicity (1 point), New York Heart Association (NYHA) functional class III (1 point) or IV (3 points), no ischemic heart disease (2 points), renal dialysis (3 points), secondary prevention indication (1 point), and single-chamber (2 points) or biventricular (1 point) ICD type. A risk score of 7 or greater was used to identify patients at high risk for defibrillation safety margin. Temporal changes in DFT among subgroups was performed using the Cochran-Mantel-Haenszel test to examine the association between categorical variables (use of DFT among different years) controlling for the hospital use of DFT in quartiles.

    Hospital variation in the use of DFT was assessed by stratifying hospitals into quartiles of all DFT across the study years. To assess the institutional level variation in use of DFT, we determined the distribution and interquartile ranges of DFT in the entire cohort and in each year. To quantify the extent to which variation was explained by hospital level effects, the hospital-specific median odds ratio (MOR) was calculated using a validated method for the entire cohort and for each year.21 Hierarchical logistic regression models were used to determine the between-hospital variance of DFT use for clustering of patients within hospital performed and the MOR was calculated. The MOR represents the odds that a randomly selected patient receiving DFT at a hospital with high testing rates would be tested than if he or she had received care at a hospital with low DFT rates. Findings were considered significant at P < .05. Data analysis was performed from May 20, 2015, to August 15, 2019, using SAS, version 9.4 (SAS Institute Inc).

    Results
    Study Population

    A total of 499 211 patients from 1794 different facilities were included in this analysis; the mean (SD) age of the population was 65.5 (13.4) years and 356 681 patients (71.4%) were men. The baseline demographics and characteristics based on DFT are included in the Table. Within the NCDR ICD registry, 915 592 patients underwent ICD implantation between April 2010 and December 2015 (Figure 1). There were 416 381 patients excluded from our final analysis owing to nontransvenous lead implantation (44 122), generator change or lead revision (371 874), prior ICD (375), and unknown use of DFT (10).

    Most patients had ischemic heart disease (286 864 [57.5%]), categorized as NYHA class II to III heart failure (414 095 [82.9%]). The mean (SD) left-ventricular ejection fraction was 28.9% (11.8%). Most patients received a device for primary prevention of sudden death (397 514 [79.6%]).

    Defibrillation Testing

    Defibrillation testing was performed in 293 660 patients (58.8%) of the entire population, of which lowest energy testing was performed in 288 841 patients (57.8%), upper limit of vulnerability in 14 741 patients (3.0%), and both methods in 9592 patients (1.9%). Patients who underwent DFT were more likely than those who did not undergo DFT to have ischemic heart disease (170 569 [58.1%] vs 116 295 [56.6%]), prior ventricular tachycardia (91 500 [31.2%] vs 58 949 [28.7%]), syncope (51 988 [17.7%] vs 32 271 [15.7%]), cardiac arrest (34 784 [11.8%] vs 21 510 [10.5%]), and less advanced NYHA class I and II heart failure (153 188 [52.2%] vs 91 215 [44.4%]) (P < .001 for all) (Table). Possible indicators of not performing DFT are described in Figure 2. There was significantly lower use of DFT among patients who had NYHA class IV (odds ratio [OR], 1.35; 95% CI, 1.30-1.40) and those with atrial arrhythmias (OR, 1.52; 95% CI, 1.47-1.56) and higher use in patients with NYHA class I categorization (OR, 0.89; 95% CI, 0.87-0.91), sinus rhythm (OR, 0.72; 95% CI, 0.70-0.74), and antiarrhythmic agent therapy (OR, 0.91; 95% CI, 0.90-0.93). There were modest but statistically significant differences in the certification of clinicians performing the implantation and use of DFT at the time of initial ICD implantation: board-certified electrophysiologist (OR, 1.00; 95% CI, 1.00-1.00); electrophysiologist fellowship or thoracic-cardiac surgery (OR,1.17; 95% CI, 1.15-1.19); pediatric cardiology (OR, 1.90; 95% CI, 1.60-2.25); and HRS guidelines (OR, 0.90; 95% CI, 0.88-0.92). Patients undergoing implantation in university settings were less likely to have DFT (OR, 1.42; 95% CI, 1.39-1.44)

    Temporal Trends and Variation in DFT

    Temporal trends in the use of DFT are depicted in Figure 3. Defibrillation testing among patients undergoing initial ICD implantation declined from 71.6% in the second calendar quarter of 2010 to 36.4% in quarter 4 of 2015 (P < .001 for trend). Among selected subgroups of patients previously outlined, there were significant differences in the rate of DFT over time for each group (all P < .001 for trend and, using Cochran-Mantel-Haenszel test for interaction, P < .001 for all). However, the difference in the rate of DFT was most evident for patients undergoing primary (71.2% vs 74.0% in 2010) vs secondary (37.7% vs 47.3% in 2015) prevention indication for implant. The difference in the rate of DFT among patients at risk for an elevated defibrillation threshold vs those not at risk was 69.4% vs 72.1% in 2010 and 37.5% vs 39.9% in 2015, respectively, and among patients with and without structural abnormalities was 74.1% vs 71.6% in 2010 and 45.7% vs 39.2% in 2015, respectively.

    Hospital-level variation in performing DFT increased over time. With a decline in the median rate of DFT, there was a corresponding increase in the interquartile range (Figure 4). The interquartile range increased from 31.7% in 2010 to 59.7% in 2015. The MOR for use of DFT in the entire cohort was 3.88 (95% CI, 3.69-4.08), which increased over time from 3.78 (95% CI, 3.54-4.03) in 2010 to 6.05 (95% CI, 5.61-6.52) in 2015, indicating that in 2015 a randomly selected patient receiving DFT at a hospital with high testing rates would have a 6-fold higher odds of being tested than if he or she had received care at a hospital with a low DFT rate. Among hospitals in the fourth quartile (most use of DFT), DFT declined from 89.6% to 78.3%; the rate in hospitals in the first quartile (least use of DFT) declined from 40.3% to 9.9% (P < .001 for trend for each).

    Outcomes After DFT

    A total of 6493 adverse events (1.3%) and 7364 adverse events or death (1.5%) occurred among patients undergoing DFT during the study period in the index hospitalization. The adjusted risk of adverse events (OR, 1.27; 95% CI, 1.21-1.34) and adverse events or death (OR, 1.31; 95% CI, 1.24-1.37) was higher in patients not receiving DFT compared with patients who underwent DFT.

    Discussion

    This study evaluating the use of DFT among 499 211 patients in the NCDR ICD Registry in 1794 US hospitals has several findings. First, the use of DFT at the time of ICD implantation appeared to decline significantly between 2010 and 2015. Second, there seemed to be variation in the use of DFT based on patient, clinician, and hospital characteristics, and the omission of DFT was possibly associated with the severity of comorbidities. Third, the temporal decline in DFT appeared to be accompanied by an increase in hospital-level variation.

    Trends in DFT

    Historically, DFT was performed in all patients undergoing ICD implantation. However, with improvements in technology, current-generation ICDs are capable of high-energy, biphasic, and tunable defibrillation waveforms such that successful defibrillation occurs in approximately 90% of clinical shocks.6,10 A post hoc analysis of the Sudden Cardiac Death in Heart Failure Trial published in 2008 demonstrated that baseline DFT did not indicate the possibility of long-term mortality or shock efficacy.8 The Shockless Implant Evaluation trial assessed the effect of DFT in patients undergoing initial left-sided ICD implantation.22 The no-testing arm was noninferior to the testing arm for the primary outcome of arrhythmic death or failed appropriate shock. A second randomized trial found that forgoing DFT was noninferior to routine DFT using a primary end point of average first-shock efficacy for ventricular tachycardia and ventricular fibrillation episodes.23 Released in 2015, an expert consensus statement on optimal ICD programming and testing provided a IIa recommendation to “omit defibrillation efficacy testing in patients undergoing initial left-pectoral transvenous ICD implantation procedures where appropriate sensing, pacing, and impedance values are obtained with fluoroscopically well-positioned RV [right ventricular] leads.”24(p70) The results of the present study may provide evidence that the use of DFT was already declining by the time that these randomized clinical trials were completed and the expert consensus statement had been released. This reduction likely reflects implanting operators’ views regarding the value of DFT based on the literature as it was published.

    Many questions remain unanswered regarding DFT owing to limited data to provide evidence-based recommendations. It is reasonable to withhold DFT among patients with severe heart failure, valvular disease, or atrial arrhythmias and subtherapeutic anticoagulation. Alternatively, it is reasonable to perform testing among patients with right-sided implants or those with advisory leads at the time of generator change, and it is recommended among patients undergoing subcutaneous ICD.24,25 Further questions remain regarding how best to approach patients whose conditions were poorly represented in trials (hypertrophic cardiomyopathy or congenital heart disease), those who are at very high risk for recurrent arrhythmias (secondary prevention indication), or those at risk for an elevated defibrillation threshold (amiodarone use, right-sided generator implants).

    We found that, while DFT has declined overall, testing in certain populations varied. For instance, patients with a secondary prevention indication and structural abnormalities were more likely to undergo testing compared with those with a primary indication and those without structural abnormalities. This difference likely reflects the fact that these patients are at higher risk of appropriate ICD therapies, in which case testing is believed to provide reassurance that the system will abort ventricular arrhythmias when needed. Alternatively, the number and severity of comorbidities appeared to be related to the omission of DFT, which reflects that patients who are sick and/or frail were preferentially chosen to not undergo DFT. Prior factors that appeared to be associated with the absence of DFT include advanced age, a history of heart failure, advanced NYHA class status, atrial arrhythmias, lower ejection fraction, a wider QRS interval, and a higher serum creatinine level.26 However, paradoxically, these patients who are not undergoing DFT may be more likely to benefit. Further studies are needed to determine which patients gain the most benefit from DFT.

    Hospital-Level Variation in Use of DFT

    We found significant hospital-level variation in the performance of DFT, which was present at the beginning of the study years and increased over time. An MOR exceeding 6 in 2015 may reflect substantial variability in DFT use. There are many plausible explanations for this variability, including the availability of anesthesia specialists to provide deep sedation, clustering of graduated fellows practicing in regions where they trained, or a monetary incentive to performing testing as there is a separate Current Procedural Terminology code for DFT that can be charged. In addition, the differences in regional use of DFT may reflect changes in payment structures in which reimbursement is bundled and there might be less incentive to perform additional procedures. However, given that hospitals in the fourth quartile (most use of DFT) had only an 11% change in use of DFT, while those in the first quartile had a 30% change in use of DFT over the study years, it seems that clinicians who routinely perform DFT have not changed their practice while others have markedly reduced their use of DFT.

    The reasons for describing this change is that a fundamental aspect to quality improvement is reducing unwarranted variation in care. Identifying hospital-level variation is a first step in understanding the extent to which patient factors influence variation in care compared with institutional factors, which can serve to be processes for interventions in attempts to improve the quality of care.

    Outcomes After DFT

    In secondary analysis, we did not find evidence that DFT was associated with harm; in fact, there was a higher risk of adverse events among patients who did not undergo DFT. However, this outcome should not be interpreted as indicating that DFT is beneficial and/or without risk, and this finding is in direct contrast to prior literature suggesting that, while rare, serious adverse events occur during DFT.13 The results of our study may be explained by 2 reasons: the number and severity of measured comorbidities was associated with the lack of DFT, such that patients who are sick and/or frail were preferentially chosen to not undergo DFT, and an effect-cause relationship, in which DFT was not performed because of an intraprocedural complications.

    Evolution of Practice Patterns

    The evolution of medicine occurs through a process of adoption and/or deadoption of practices. More often, there is a focus on adoption of newer interventions that outperform established practices. However, there must also be deadoption of established standards, not because a better intervention has been developed, but because what was once thought to be beneficial is not. A well-recognized example of this was the previously held belief that suppression of ventricular ectopy following acute myocardial infarction, which was an independent predictor of mortality, would improve arrhythmic death. However, the use of class 1C drugs, which successfully reduced ventricular ectopy, also resulted in an excess of mortality; thus, there was a deadoption of the use of class 1C drugs among patients with structural heart disease.27 There are numerous other examples of deadoption, which are best seen in the evolving changes in clinical guidelines.28,29 The present study may provide a perspective on the pace of deadoption of a once-held belief that DFT needs to be performed during ICD implantation. Despite mounting evidence that omission of DFT is safe, there is still significant variation in its use, with some institutions continuing to apply DFT frequently, which is independent of patient characteristics. As with adoption, deadoption requires a focus on the cultural aspects of practice, which have evolved from not only evidence-based practices, but also personal experiences, conflicts, and biases.

    Limitations

    This study has limitations. Certain factors should be considered in the interpretation of the findings. First, the reasons behind decisions to perform or not perform DFT are not gathered from the NCDR ICD Registry. Second, the decision on use of DFT in a small portion of patients was based on their upper limit of vulnerability, which does not necessarily have the same risks as the lowest energy required (ie, patients do not need to have induction of ventricular fibrillation during the upper limit of vulnerability). In addition, defibrillation threshold testing is likely a misnomer for many centers in which a single shock of 10 to 15 J or greater is an acceptable defibrillation safety margin. Third, high-risk features exist for an elevated defibrillation threshold, including right-sided generator implants, which are not recorded in the NCDR ICD Registry. In addition, more contemporary data beyond 2015 would be insightful to describe the patterns in use of DFT, particularly because both randomized clinical trials and the expert consensus statement were published at the end of the time of data acquisition; however, at the time of our study, this information was not available for analysis owing to changes in the NCDR ICD Registry data collection form.

    Conclusions

    There appears to have been a significant reduction in the use of DFT for initial ICD implantation in US hospitals over time, declining from 72% in the first quarter of 2010 to 36% in the last quarter of 2015. Yet, although the overall use of DFT has declined, there has been an increase in the institutional variability in performing DFT with an increase in the MOR from 3.78 in 2010 to 6.05 in 2015. This variability in deadoption of DFT could reflect differences in practice culture despite mounting evidence and guidance that DFT may not be necessary at the time of ICD implantation.

    Back to top
    Article Information

    Accepted for Publication: August 31, 2019.

    Published: October 18, 2019. doi:10.1001/jamanetworkopen.2019.13553

    Open Access: This is an open access article distributed under the terms of the CC-BY License. © 2019 Borne RT et al. JAMA Network Open.

    Corresponding Author: Ryan T. Borne, MD, Division of Cardiology, University of Colorado Anschutz Medical Campus, 12631 E 17th Ave, Campus Box B130, Aurora, CO 80045 (ryan.borne@ucdenver.edu).

    Author Contributions: Dr Borne had full access to all of the data in the study and takes responsibility for the integrity of the data and the accuracy of the data analysis.

    Concept and design: Borne, Randolph, Peterson, Thomas, Hsu, Russo.

    Acquisition, analysis, or interpretation of data: Borne, Randolph, Wang, Curtis, Peterson, Masoudi, Sandhu, Zipse, Thomas, Kutyifa, Desai, Cha, Russo.

    Drafting of the manuscript: Borne, Masoudi.

    Critical revision of the manuscript for important intellectual content: All authors.

    Statistical analysis: Borne, Randolph, Wang, Curtis, Sandhu.

    Administrative, technical, or material support: Borne, Randolph, Masoudi, Zipse, Desai.

    Supervision: Borne, Zipse, Thomas, Russo.

    Conflict of Interest Disclosures: Dr Curtis reported having a contract with the American College of Cardiology for his role as Senior Medical Officer, NCDR; receives salary support from the American College of Cardiology, NCDR. receives funding from the Centers for Medicare & Medicaid Services to develop and maintain performance measures that are used for public reporting; and holds equity interest in Medtronic. Dr Peterson reported receiving personal fees from the American Heart Association, as well as grants from the National Heart, Lung, and Blood Institute and AstraZeneca outside the submitted work. Dr Masoudi reported receiving grants from the American College of Cardiology outside the submitted work. Dr Zipse reported receiving personal fees from Medtronic and Spectranetics outside the submitted work. Dr Kutyifa reported receiving research grants from Boston Scientific, ZOLL, and Biotronik, and consultant fees from ZOLL and Biotronik outside the submitted work. Dr Desai reported working under contract with the Centers for Medicare & Medicaid Services to develop and maintain performance measures used for public reporting and pay for performance programs, as well as paid consulting for Amgen, Boehringer Ingelheim, Cytokinetics, Relypsa, and Novartis. Dr Hsu reported receiving personal fees from Medtronic, Boston Scientific, Abbott, Biotronik, Pfizer, and Bristol-Myers Squibb, and grants from Biotronik and Biosense-Webster outside the submitted work. Dr Russo reported receiving nonfinancial support from the American College of Cardiology Foundation during the conduct of the study, grants from Boston Scientific, and personal fees from Boston Scientific, Medtronic, and UpToDate outside the submitted work. No other disclosures were reported.

    Funding/Support: This research was supported by the American College of Cardiology Foundation’s National Cardiovascular Data Registry (NCDR).

    Role of the Funder/Sponsor: The American College of Cardiology Foundation had no role in the design and conduct of the study; collection, management, analysis, and interpretation of the data; preparation, review, or approval of the manuscript; and decision to submit the manuscript for publication.

    Disclaimer: The views expressed in this article represent those of the authors, and do not necessarily represent the official views of the NCDR or its associated professional societies identified at http://www.ncdr.com.

    References
    1.
    Moss  AJ, Zareba  W, Hall  WJ,  et al; Multicenter Automatic Defibrillator Implantation Trial II Investigators.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.  N Engl J Med. 2002;346(12):877-883. doi:10.1056/NEJMoa013474PubMedGoogle ScholarCrossref
    2.
    Kadish  A, Dyer  A, Daubert  JP,  et al; Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) Investigators.  Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy.  N Engl J Med. 2004;350(21):2151-2158. doi:10.1056/NEJMoa033088PubMedGoogle ScholarCrossref
    3.
    Bardy  GH, Lee  KL, Mark  DB,  et al; Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.  N Engl J Med. 2005;352(3):225-237. doi:10.1056/NEJMoa043399PubMedGoogle ScholarCrossref
    4.
    Epstein  AE, DiMarco  JP, Ellenbogen  KA,  et al; American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices); American Association for Thoracic Surgery; Society of Thoracic Surgeons.  ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons.  Circulation. 2008;117:e350-e408.PubMedGoogle Scholar
    5.
    Tracy  CM, Epstein  AE, Darbar  D,  et al.  2012 ACCF/AHA/HRS focused update of the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines.  J Am Coll Cardiol. 2012;60:1297-1313. doi:10.1016/j.jacc.2012.07.009PubMedGoogle ScholarCrossref
    6.
    Russo  AM, Chung  MK.  Is defibrillation testing necessary for implantable transvenous defibrillators? defibrillation testing is necessary at the time of implantable cardioverter defibrillator implantation.  Circ Arrhythm Electrophysiol. 2014;7(2):337-346. doi:10.1161/CIRCEP.113.000371PubMedGoogle ScholarCrossref
    7.
    Swerdlow  CD, Russo  AM, Degroot  PJ.  The dilemma of ICD implant testing.  Pacing Clin Electrophysiol. 2007;30(5):675-700. doi:10.1111/j.1540-8159.2007.00730.xPubMedGoogle ScholarCrossref
    8.
    Blatt  JA, Poole  JE, Johnson  GW,  et al; SCD-HeFT Investigators.  No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).  J Am Coll Cardiol. 2008;52(7):551-556. doi:10.1016/j.jacc.2008.04.051PubMedGoogle ScholarCrossref
    9.
    Matassini  MV, Healey  JS.  How to manage a high defibrillation threshold in ICD patients and does it really matter.  Curr Treat Options Cardiovasc Med. 2013;15(4):497-505. doi:10.1007/s11936-013-0244-7PubMedGoogle ScholarCrossref
    10.
    Pires  LA, Johnson  KM.  Intraoperative testing of the implantable cardioverter-defibrillator: how much is enough?  J Cardiovasc Electrophysiol. 2006;17(2):140-145. doi:10.1111/j.1540-8167.2005.00294.xPubMedGoogle ScholarCrossref
    11.
    Healey  JS, Gula  LJ, Birnie  DH,  et al.  A randomized-controlled pilot study comparing ICD implantation with and without intraoperative defibrillation testing in patients with heart failure and severe left ventricular dysfunction: a substudy of the RAFT trial.  J Cardiovasc Electrophysiol. 2012;23(12):1313-1316. doi:10.1111/j.1540-8167.2012.02393.xPubMedGoogle ScholarCrossref
    12.
    Brignole  M, Occhetta  E, Bongiorni  MG,  et al; SAFE-ICD Study Investigators.  Clinical evaluation of defibrillation testing in an unselected population of 2,120 consecutive patients undergoing first implantable cardioverter-defibrillator implant.  J Am Coll Cardiol. 2012;60(11):981-987. doi:10.1016/j.jacc.2012.05.014PubMedGoogle ScholarCrossref
    13.
    Birnie  D, Tung  S, Simpson  C,  et al.  Complications associated with defibrillation threshold testing: the Canadian experience.  Heart Rhythm. 2008;5(3):387-390. doi:10.1016/j.hrthm.2007.11.018PubMedGoogle ScholarCrossref
    14.
    Poole  JE, Johnson  GW, Hellkamp  AS,  et al.  Prognostic importance of defibrillator shocks in patients with heart failure.  N Engl J Med. 2008;359:1009-1017. doi:10.1056/NEJMoa071098PubMedGoogle ScholarCrossref
    15.
    Hohnloser  SH, Dorian  P, Roberts  R,  et al.  Effect of amiodarone and sotalol on ventricular defibrillation threshold: the optimal pharmacological therapy in cardioverter defibrillator patients (OPTIC) trial.  Circulation. 2006;114(2):104-109. doi:10.1161/CIRCULATIONAHA.106.618421PubMedGoogle ScholarCrossref
    16.
    Gold  MR, Higgins  S, Klein  R,  et al.  Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS).  Circulation. 2002;105(17):2043-2048. doi:10.1161/01.CIR.0000015508.59749.F5PubMedGoogle ScholarCrossref
    17.
    Hammill  S, Phurrough  S, Brindis  R.  The National ICD Registry: now and into the future.  Heart Rhythm. 2006;3(4):470-473. doi:10.1016/j.hrthm.2006.01.019PubMedGoogle ScholarCrossref
    18.
    Masoudi  FA, Ponirakis  A, de Lemos  JA,  et al.  Trends in US cardiovascular care: 2016 report from 4 ACC national cardiovascular data registries.  J Am Coll Cardiol. 2017;69(11):1427-1450. doi:10.1016/j.jacc.2016.12.005PubMedGoogle ScholarCrossref
    19.
    Messenger  JC, Ho  KKL, Young  CH,  et al; NCDR Science and Quality Oversight Committee Data Quality Workgroup.  The National Cardiovascular Data Registry (NCDR) data quality brief: The NCDR data quality program in 2012.  J Am Coll Cardiol. 2012;60(16):1484-1488. doi:10.1016/j.jacc.2012.07.020PubMedGoogle ScholarCrossref
    20.
    Hsu  JC, Marcus  GM, Al-Khatib  SM,  et al.  Predictors of an inadequate defibrillation safety margin at ICD implantation: insights from the National Cardiovascular Data Registry.  J Am Coll Cardiol. 2014;64(3):256-264. doi:10.1016/j.jacc.2014.01.085PubMedGoogle ScholarCrossref
    21.
    Merlo  J, Chaix  B, Ohlsson  H,  et al.  A brief conceptual tutorial of multilevel analysis in social epidemiology: using measures of clustering in multilevel logistic regression to investigate contextual phenomena.  J Epidemiol Community Health. 2006;60(4):290-297. doi:10.1136/jech.2004.029454PubMedGoogle ScholarCrossref
    22.
    Healey  JS, Hohnloser  SH, Glikson  M,  et al; Shockless IMPLant Evaluation [SIMPLE] Investigators.  Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE).  Lancet. 2015;385(9970):785-791. doi:10.1016/S0140-6736(14)61903-6PubMedGoogle ScholarCrossref
    23.
    Bänsch  D, Bonnemeier  H, Brandt  J,  et al; NORDIC ICD Trial Investigators.  Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial.  Eur Heart J. 2015;36(37):2500-2507. doi:10.1093/eurheartj/ehv292PubMedGoogle ScholarCrossref
    24.
    Wilkoff  BL, Fauchier  L, Stiles  MK,  et al.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing.  Heart Rhythm. 2016;13(2):e50-e86. doi:10.1016/j.hrthm.2015.11.018PubMedGoogle ScholarCrossref
    25.
    Pires  LA.  Defibrillation testing of the implantable cardioverter defibrillator: when, how, and by whom?  Indian Pacing Electrophysiol J. 2007;7(3):166-175.PubMedGoogle Scholar
    26.
    Russo  AM, Wang  Y, Al-Khatib  SM, Curtis  JP, Lampert  R.  Patient, physician, and procedural factors influencing the use of defibrillation testing during initial implantable cardioverter defibrillator insertion: findings from the NCDR®.  Pacing Clin Electrophysiol. 2013;36(12):1522-1531. doi:10.1111/pace.12248PubMedGoogle ScholarCrossref
    27.
    Echt  DS, Liebson  PR, Mitchell  LB,  et al.  Mortality and morbidity in patients receiving encainide, flecainide, or placebo: the Cardiac Arrhythmia Suppression Trial.  N Engl J Med. 1991;324(12):781-788. doi:10.1056/NEJM199103213241201PubMedGoogle ScholarCrossref
    28.
    Han  H, Chao  H, Guerra  A,  et al.  Evolution of the American College of Cardiology/American Heart Association Clinical Guidelines.  J Am Coll Cardiol. 2015;65(25):2726-2734. doi:10.1016/j.jacc.2015.04.050PubMedGoogle ScholarCrossref
    29.
    Neuman  MD, Goldstein  JN, Cirullo  MA, Schwartz  JS.  Durability of class I American College of Cardiology/American Heart Association clinical practice guideline recommendations.  JAMA. 2014;311(20):2092-2100. doi:10.1001/jama.2014.4949PubMedGoogle ScholarCrossref
    ×